112 research outputs found

    Measurement of angular distributions by use of low-coherence interferometry for light-scattering spectroscopy

    Get PDF
    We present a novel interferometer for measuring angular distributions of backscattered light. The new system exploits a low-coherence source in a modified Michelson interferometer to provide depth resolution, as in optical coherence tomography, but includes an imaging system that permits the angle of the reference field to be varied in the detector plane by simple translation of an optical element. We employ this system to examine the angular distribution of light scattered by polystyrene microspheres. The measured data indicate that size information can be recovered from angular-scattering distributions and that the coherence length of the source influences the applicability of Mie theory

    Phase-dispersion optical tomography

    Get PDF
    We report on phase-dispersion optical tomography, a new imaging technique based on phase measurements using low-coherence interferometry. The technique simultaneously probes the target with fundamental and second-harmonic light and interferometrically measures the relative phase shift of the backscattered light fields. This phase change can arise either from reflection at an interface within a sample or from bulk refraction. We show that this highly sensitive 5 phase technique can complement optical coherence tomography, which measures electric field amplitude, by revealing otherwise undetectable dispersive variations in the sample

    Cavity ring-down technique and its application to the measurement of ultraslow velocities

    Get PDF
    We have developed a new ring-down technique that does not require a shutter to turn a probe laser on and off. With a rapid cavity scan we can measure a simple exponential cavity decay from which a cavity finesse can be found. When the cavity is scanned slowly, the cavity decay exhibits an amplitude modulation, and an analytic expression is derived for this modulation. With this new technique we measured the ultraslow relative velocity of the mirrors (of the order of micrometers per second) as well as the linewidth (~100 kHz) of the probe laser

    Spatial coherence of forward-scattered light in a turbid medium

    Get PDF
    We study spatially coherent forward-scattered light propagating in a turbid medium of moderate optical depth (0-9 mean free paths). Coherent detection was achieved by using a tilted heterodyne geometry, which desensitizes coherent detection of the attenuated incident light. We show that the degree of spatial coherence is significantly higher for light scattered only once in comparison with that for multiply scattered light and that it approaches a small constant value for large numbers of scattering events

    Determination of particle size by using the angular distribution of backscattered light as measured with low-coherence interferometry

    Get PDF
    We employ a novel interferometer to measure the angular distribution of light backscattered by a turbid medium. Through comparison of the measured data with the predictions of Mie theory, we are able to determine the size of the scatterers comprising the medium with subwavelength precision. As the technique is based on low-coherence interferometry, we are able to examine the evolution of the angular distribution of scattered light as it propagates into the medium. The effects of multiple scattering as a function of penetration depth in the medium are analyzed. We also present various considerations for extending this technique to determining structural information in biological tissues, such as the effects of a distribution of particle sizes and the need to average out speckle contributions

    Phase-referenced interferometer with subwavelength and subhertz sensitivity applied to the study of cell membrane dynamics

    Get PDF
    We report a highly sensitive means of measuring cellular dynamics with a novel interferometer that can measure motional phase changes. The system is based on a modified Michelson interferometer with a composite laser beam of 1550-nm low-coherence light and 775-nm CW light. The sample is prepared on a coverslip that is highly reflective at 775nm. By referencing the heterodyne phase of the 1550-nm light reflected from the sample to that of the 775-nm light reflected from the coverslip, small motions in the sample are detected, and motional artifacts from vibrations in the interferometer are completely eliminated. We demonstrate that the system is sensitive to motions as small as 3.6nm and velocities as small as 1nm/s. Using the instrument, we study transient volume changes of a few (approximately three) cells in a monolayer immersed in weakly hypotonic and hypertonic solutions

    Angular light scattering studies using low-coherence interferometry

    Get PDF
    A modified Michelson interferometer is used to measure path- length resolved angular distributions of light backscattered by turbid media. The path length resolution is obtained by exploiting the coherence properties of a broadband source. The angular distribution is mapped out using a simple optical system to scan the angle at which the reference field intersects the detector plane. Angular scattering distributions can be compared to Mie theory to determine the size and refractive index of spherical scatterers. Initial studies utilizing this system demonstrate the potential of low coherence interferometry for obtaining structural information using angular distributions

    Interferometric phase-based dual-wavelength tomography

    Get PDF
    We describe our phase-sensitive interferometry technique implemented as phase dispersion microscopy (PDM)/optical tomography (PDOT). The technique is based on measuring the phase difference between fundamental and second harmonic low coherence light in a novel interferometer. We attain high sensitivity to subtle refractive index differences due to dispersion with a differential optical path sensitivity of 5 nm. Using PDM, we show that ballistic light in a turbid medium undergoes a phase velocity change that is dependent on scatterer size. We demonstrate that the microscopy technique performs better than a conventional phase contrast microscope in imaging dispersive and weakly scattering samples. The tomographic implementation of the technique (PDOT) can complement Optical Coherence Tomography (OCT) by providing phase information about the scanned object

    Interferometric phase-dispersion microscopy

    Get PDF
    We describe a new scanning microscopy technique, phase-dispersion microscopy (PDM). The technique is based on measuring the phase difference between the fundamental and the second-harmonic light in a novel interferometer. PDM is highly sensitive to subtle refractive-index differences that are due to dispersion (differential optical path sensitivity, 5 nm). We apply PDM to measure minute amounts of DNA in solution and to study biological tissue sections. We demonstrate that PDM performs better than conventional phase-contrast microscopy in imaging dispersive and weakly scattering samples
    corecore